Lost water circuits (trout and carp)

Lost water circuits (trout and carp)

PO." : Open pathogens

vue sur des circuits PO avec aquariums en zone d'expérimentation
vue sur des circuits PO avec aquariums en zone d'expérimentation

CIRCUITS IN ONE MODE: IN LOST WATER

6 independent circuits (PO1 to PO6)

6 open pathogens (6 PO from 8 to 10 aquariums (15L)), circuits running only in Lost Water

- PO 1 to 4 with 10 aquariums

- PO 5 and 6 with 8 aquariums

Technical description

Open circuit (continuous supply of dechlorinated city water) with temperature control. Temperature range: 5-20 ° C. Cooling / heating system via plate exchanger (brine) or via a heater.

Temperature, O2 under supervision via supervision software (Centralized Technical Management)

Water treatment

Dechlorinated city water via activated charcoal filter

Available Flow

 

 ~ 20 l / h per aquarium (visualizable with flow meter of the installations)
 

Temperature

Regulated temperature (5-20 ° C)
 

Oxygen

Instructions: The oxygen level is maintained above 7 mg / l.

Oxygen supply via individual air diffusers in each aquarium

Photoperiod

Adjustable lighting ranges (on programmed clocks) with progressive lighting and extinction for the entire "trypanos pathogens" experimental room housing all independent circuits.

Contact

RIGAUDEAU Dimitri

Centre des recherches INRA de Jouy en Josas

Domaine de Vilvert, bâtiment 234
78350 Jouy en Josas, France
Tél. : +33 (0)1 34 65 28 53